Products


Capacitor Banks

Posted by on ۴:۵۰ ب.ظ in Uncategorized, Uncategorized @fa | ۰ comments

Capacitor Banks

  Capacitor Banks Robust & modular structure Suitable for indoor & outdoor installation Power factor correction of reactive loads Specifications:  Max Voltage: 400V-20KV Cell capacity: up to 500kvar Degree of Protection: IP44 Capacitor: dry capacitors, gas capacitors, oil capacitors Intelligent reactive power controller Network harmonic...

read more

Automatic Transfer Switch (ATS)

Posted by on ۴:۴۳ ب.ظ in Uncategorized @fa | ۰ comments

Automatic Transfer Switch (ATS)

AUTOMATIC TRANSFER SWITCH Specifications: Max Voltage: 400V – 20KV Control Voltage: 12 to 220VAC/DC Control by HMI Ability to multi-generator paralleling with the grid Degree of Protection: IP 44 , 54...

read more

Industrial Automation

Posted by on ۴:۳۷ ب.ظ in Uncategorized @fa | ۰ comments

Industrial Automation

Industrial Automation and Control : Specifications PLC: SIEMENS HMI: SIEMENS Devices: SIEMENS, Télémécanique, Schneider Degree of Protection: IP 44, 54...

read more

Motor Control Center

Posted by on ۴:۲۹ ب.ظ in Uncategorized @fa | ۰ comments

Motor Control Center

Motor Control Center Specifications: Max Voltage: 400V -6kc AC – DC Max Voltage:400V Max Current: 200A TO 6300A UP Degree of Protection: IP44 – 54 Model: Fixed , Slide , Modular...

read more

Electrolysis Rectifier Transformer

Posted by on ۴:۱۴ ب.ظ in Uncategorized @fa | ۰ comments

Electrolysis Rectifier Transformer

ELECTROLYSIS RECTIFIER TRANSFORMER OPTIONS: Control and protection PLC & HMI Remot Control Systems Rectifiers in parallel Local Remot Register moment to moment monitoring and recording system errors (Data Logging System) Cooling Transformer & Rectifier Pump & Fan by PID Control System Specifications: Installation of a transformerModel Transformer & Rectifier: TDW- TTW – TTDW – TDA – TTA – TTDA – TDO – TTO – TTDO Transformator Cooling: ONAN – ONAF – OFAF – OFAN – ODAF – OFWF Rectifier Cooling: Closed Flow – Water Cooling de-mineralized water – Oil Colling – Air Cooling Indoor or Outdoor Pulse Number Per Unit:3 pulse-6 Pulse -12 Pulse – 24 Pulse Type of semiconductor: diode or thyristor Rectifier connection: bridge or single way DC voltage control: Coarse regulation on-load tap changer (OLTC) – Fine regulation: thyristor phase angle DC current control: thyristor firing angle Max Voltage:0-1000VDC Max Current:0-100KA Control accuracy and high efficiency Control current and voltage ramp separately Ambient conditions: – 40°C… + 70°C Degree of Protection: IP21 –...

read more

Power Distribution Systems

Posted by on ۴:۰۲ ب.ظ in Uncategorized @fa | ۰ comments

Power Distribution Systems

POWER DISTRIBUTION SYSTEMS Specifications: M Max Voltage: 400V Max Current: 400A – 6300A Degree of Protection: IP44 Fuse use: ACB – MCCB – MCB – Cartridge – Slide...

read more

Slim – Switchgear Compact

Posted by on ۳:۴۶ ب.ظ in Uncategorized @fa | ۰ comments

Slim – Switchgear Compact

SLIM-SWITCHGEAR COMPACT Compartments segregated by metallic partitions LV compartment for control, protection and metering instruments Relay digital secondary power supply by inside & external Control capabilities in automation systems Designed for different weather conditions Degree of Protection: IP44 : Specifications Model: SSH. SM6 Max Voltage:7.2KV-24KV Max Current:630A-1250A Disconnector: SF6 , VACUM CirCuit Breaker:SF6 , VACUM Designed for medium voltage distribution Factory – tested for indoor installations Complete with me mechanical safety interlocks Enclosure made of galvanized sheet steel...

read more

Medium Voltage Air Insulated Secondary Distribution Switchgear

Posted by on ۳:۳۶ ب.ظ in Uncategorized @fa | ۰ comments

Medium Voltage Air Insulated Secondary Distribution Switchgear

MV AIS SECONDARY DISTRIBUTION SWITCHGEAR Specifications: Max Voltage: 7.2KV – 24KV Max Current: 630A-1250A Disconnector: ON LOAD BERAKER & OFF LOAD BERAKER CirCuit Beraker: SF6 , VACUM Enclosure made of galvanized sheet steel Control system: with digital relay protection Degree of Protection: IP33  ...

read more

Drive & Motor Soft Starter

Posted by on ۶:۵۵ ق.ظ in Uncategorized @fa | ۰ comments

Drive & Motor Soft Starter

DRIVES AND SOFT-STARTERS Specifications: Max Voltage:230V-400V-20KV Max Current: 0-2600A UP Max HZ:0-1000HZ Max Watt:1200 KW Degree of Protection: IP21. 23. 44. 54...

read more

Compact Secondary Substations

Posted by on ۱۲:۲۸ ب.ظ in Uncategorized @fa | ۰ comments

Compact Secondary Substations

COMPACT SECONDARY SUBSTATIONS Transformers: Dry former, Hermetically, Oil Transformer Stableinany Conditions:(-25°c…+45°c) Withstand internal Arc: 20KA Frequency: 50-60hz Specifications: Installation of a transformer Transformer capacity:1600KVA Transformer replace: rails, folding in the sides Max Voltage: 36KV Max Current: 1250A Enclosure made of galvanized sheet steel Installation: GIS, AIS Degree of Protection: IP44  ...

read more